All about ZONT alarm system. GSM thermostat "GSM-Climate ZONT H1". Buy from an official dealer. Favorable price. Delivery throughout the Russian Federation! Umbrella boiler control system

Remote control unit for boiler ZONT H-1 GSM-Climate

  • Supply voltage 10-14 V
  • Maximum current consumption 150 mA
  • Maximum current through relay contacts 1000 mA
  • GSM modem frequency ranges 800, 900, 1800, 1900 MHz
  • Weight: 200 g

ZONT H-1 GSM-Climate is a modern device for controlling a heating boiler via the Internet and telephone.

It automatically controls the operation of the boiler, monitors its technical condition and signals when an accident occurs or the supply voltage is cut off.

Comfortable temperature:

Using ZONT H-1 GSM-Climate, you can remotely change the operating parameters of the heating system and control the room temperature. At the same time, it is possible to switch to the “Economy” or “Comfort” fixed temperature mode, create a weekly “Schedule” for the operation of the heating boiler, or turn it off remotely.
ZONT H-1 GSM-Climate independently monitors the readings of a digital air temperature sensor and adjusts the operation of the boiler depending on the specified parameters temperature regime indoors.

Remote control:

ZONT H-1 GSM-Climate is a compact device with its own SIM card, connected to a heating boiler. Commands can be sent to it from any phone (satellite, mobile or fixed line), tablet or PC. Remote control requires a unique password to be entered, preventing unauthorized access.

An additional “Alarm input” provides the connection of an unlimited number of similar detectors: motion or disconnection sensors, fire and smoke alarms, water leakage or gas leakage sensors and other similar equipment. Information is transmitted via mobile communications and the Internet. You simply indicate in the system settings the necessary telephone numbers for notification: yours or the security organization.

How does ZONT H-1 work in alarm mode?

Equipment selected depending on the task being solved is installed in the room, for example, sensors that respond to movement. Such sensors detect the presence of strangers in the house and send a signal to the unit’s GSM modem. The alarm notification is sent to programmed phone numbers as a voice call or SMS message, and is also displayed in personal account online service. Thus, you can quickly make a decision to protect your property: call the police or simply call your neighbors.

Of course, the main function of ZONT H-1 is to control the operation of the heating boiler. But you must admit that ensuring home security is a very useful feature of this “smart” device. Moreover, we are talking not only about protection from the entry of unauthorized persons, but also from other risks: fire, water and gas leaks.That is, it is also a kind of insurance against everyday troubles.

Free WEB service:

  • Checking the health of an electric or gas boiler
  • Informing about an accident and loss of supply voltage
  • Controlling boiler operating modes from your phone and via the Internet
  • Indoor air temperature monitoring
  • Maintaining room temperature according to an individual schedule
  • Alerts about alarm input sensors (GSM alarm)
  • User-friendly interface and mobile applications for iOS and Android

Energy Saving:

If you are only at home on weekends or in the evening/night, the ZONT H-1 GSM-Climate control unit will maintain a minimum temperature in the house during your absence, saving energy resources, and when you return, it will create comfortable conditions in the house.

Functionality:

Free WEB interface:

  • constant connection with the server
  • recording and automatic transmission accumulated information
  • display of boiler status:
    • current operating mode
    • room temperature
    • emergency mode indication
  • changing the boiler operating mode “in one click”
  • temperature monitoring for any period of time
  • weekly temperature schedule editor
  • notifications about activation of additional sensors (Alarm input)

Boiler operation control:

  • SMS commands
  • dialing to voice menu
  • via the Internet

Event Notification:

  • t change below the set threshold
  • t change above the set threshold
  • boiler accident
  • temperature sensor malfunction
  • loss and reappearance of supply voltage
  • triggering of “Alarm input” sensors

Event memory:

  • room temperature values ​​at any time
  • date and time of the boiler failure
  • date and time of change of operating mode
  • executed voice menu commands
  • sent SMS
  • update date and time software(BY)
  • date and time of power on/off

Specifications:

Supply voltage 10-14 V
Maximum current consumption 150 mA
One analog input Yes
One dry contact output (make/break) Yes
Maximum current through relay contacts 1000 mA
Voice interface Yes
WEB interface Yes
1-Wire interface Yes
Operating temperature range from -30 to +55 °С
GSM modem frequency ranges 800, 900, 1800, 1900 MHz
GPRS data channel Yes
Backup battery BL-5C (optional) sold separately
Time to reach operating mode no more than 50 sec
Dimensions 77 x 86 x 33 mm
Weight 200 gr
Housing material Plastic

Equipment:

  • Thermostat (Main unit of the system) - 1 pc.
  • Mounting base - 1 pc.
  • Digital sensor temperature - 1 pc.
  • Terminal block (2 pcs.) - 1 pc.
  • Network adapter 220/12 V - 1 pc.
  • GSM antenna - 1 pc.
Supply voltage 10-28V
Maximum current consumption 150 mA
Number of analog inputs 1
Output dry contact (make/open) 1
Type of connected wired temperature sensors DS 18S20
Type of connected radio thermal sensors ,
Total number of simultaneously connected temperature sensors 10
Maximum permissible length of cable with temperature sensors 100 m
Maximum current through relay contacts 1000 mA
Maximum voltage of switched relay contacts ~ 220 V, = 24 V
Voice interface There is
WEB interface There is
1-Wire interface There is
Operating temperature range from -30 to +55 °C
GSM modem frequency ranges 800, 900, 1800, 1900 MHz
Data link GPRS
GSM antenna external
Internal non-volatile memory There is
Built-in battery backup 103450-RSV-LD 2000 mAh
Time to reach operating mode no more than 50 sec
Average service life 7 years
Dimensions 90 x 50 x 55
Weight, no more 0.200 kg
Housing material Plastic on DIN rail

WEB interface

  • display of the current state of the boiler and room temperature;
  • boiler operation control;
  • temperature monitoring (inside, outside, coolant) for any selected period of time;
  • programming boiler operation according to schedule;
  • notifications about the activation of additional sensors.
  • Remote control of boiler operation

    • management of SMS commands;
    • control when dialing to the voice menu;
    • control via the Internet (WEB interface and mobile application for Android and iOS devices).

    Event Notification

    • notification when the measured temperature deviates from the specified threshold values;
    • notification of a boiler failure (provided the thermostat is connected to the emergency output of the boiler);
    • notification of a malfunction of the temperature sensor and the thermostat going into emergency mode work;
    • notification of power loss/restoration (mains) (only when the backup battery is turned on);

    Signaling

    monitoring the status of additional sensors connected to the “Alarm” input of the thermostat;

    Event memory

    • a diary of measured temperatures for any period without a statute of limitations;
    • date and time of detection of the boiler failure;
    • date and time of changing the operating mode of the boiler and thermostat;
    • executed control commands via voice menu, transmitted by SMS, software updates;
    • date and time of power failure/restoration (network).

    Remote software update

    Updating the current version of the unit's firmware without turning it off or dismantling it.

    Thermostat for controlling any electric, gas or diesel boiler.

    ZONT H-1V Intelligent thermostat for remote control of the heating boiler. When installing a ZONT thermostat, it is possible to simultaneously connect 10 temperature sensors, which allows you to control the temperature in different rooms. For example, the temperature outside, the temperature in the room, in the boiler room, the temperature of the boiler supply, return, boiler, heated floor, etc. A time graph is constructed for each temperature sensor. You can view temperature changes over a day, over a week, or over any other period of time.


    In the event of a power failure, emergency operation of the boiler, or the boiler operating parameters exceeding certain limits, an SMS notification, a telephone call or an email notification occurs. The operation of the boiler can be adjusted using any of the temperature sensors. You can set the comfortable, economical and anti-freeze operating modes. In addition, it is possible to program the desired temperature by time of day throughout the week. Weather-dependent control (PZA) of boiler operation according to temperature curves. In PZA mode, the thermostat controls the coolant temperature based on the outside street temperature. When connecting an additional adapter it is possible remote control boiler using the Open Therm protocol, with the transmission of possible error codes and other parameters of the boiler operation.


    The device operates via a GPRS channel using an installed SIM card. The data is sent to a free cloud server. It can be controlled using SMS commands or using voice control, which is undoubtedly convenient for older people who do not use smartphones and tablets. The cost of the Reception tariff plan, a standard SIM card, is about 120 rubles per month. For ease of use, there are free phone applications and a personal account on the website. You can connect motion sensors, water leakage sensors, gas leakage sensors to the thermostat, with arming and disarming and corresponding notification when triggered. When the sensors are triggered or when a boiler alarm signal appears, the device will notify you via the phone numbers specified during setup. All settings are made independently or with the help of an installer, remotely via the Internet and your personal account. When the main power is turned off, the device sends notification information and switches to operation from the built-in battery.

    The minimum set of the device includes the thermostat itself with a power supply, one temperature sensor which will be used for control, and a SIM card

    “ZONT H-1” is a module for remote monitoring and control of a heating boiler. Configuration and management are carried out via GSM channel and via the Internet. In accordance with the specified parameters, it automatically regulates the operation of the boiler in heating mode to maintain the desired temperature in the room. Also, the device can monitor the technical condition of the boiler and signal a malfunction if an accident occurs or the power supply is cut off.

    Why should you buy "ZONT H-1"

    • Control from your phone, tablet or computer. Commands can be sent to the thermostat from any phone, tablet or PC. For ease of use, there are free phone applications and a personal account on the website. To protect against unauthorized access, access to your personal account is password protected.
    • Individual setting of operating modes. It is possible to set up several home heating modes in advance, so that in the future you can select the desired mode at the moment with one movement.
    • 10 temperature sensors for any purpose. You can simultaneously connect 10 temperature sensors (wired or radio sensors) to the thermostat. The main readings are used to control the operation of the boiler. An additional one is assigned to his reserve. If the main thermostat malfunctions, it automatically switches to operation using the backup sensor and control of the boiler does not stop. The readings of the remaining sensors are used for general monitoring of the heating system.
    • Alert system for all occasions. The thermostat controls the temperature in the house and outside, supply voltage, technical condition of the boiler and much more. If the values ​​deviate from the specified ones, it informs you about this by call or SMS message.
    • Easy installation, which does not require special skills. Easily connects to an electric or gas boiler instead of a room thermostat. A SIM card of any operator that provides stable reception is inserted into the device, and the supply voltage is supplied. You need to send an SMS to the SIM card number from the owner’s phone and “introduce” the devices.

    Capabilities of the GSM module “ZONT H1”

    • Through a free WEB interface, the following options are provided: real-time display of the current state of the boiler and the temperature in the room, control of the boiler operating mode, monitoring of temperatures (inside, outside the room, coolant) for any selected period of time, programming the boiler operation according to a weekly schedule, display notifications about the activation of additionally installed sensors.
    • Remote control of the boiler operation can be carried out via SMS, dialing the voice menu, via the Internet (WEB interface and mobile application for Android and iOS devices).
    • Notification of events: deviation of the measured temperature from the specified threshold values, boiler failure (provided the thermostat is connected to the emergency output of the boiler), malfunction of the temperature sensor and transition of the thermostat to emergency operation mode, loss/restoration of power (mains) (only with a backup battery installed) .
    • Using the module for GSM security - monitoring the status of additional sensors (security or water leaks/gas leaks) connected to the “Alarm” input of the thermostat.
    • Event memory: diary of measured temperatures for any period without a statute of limitations, date and time of detection of a boiler failure, date and time of change in the operating mode of the boiler and thermostat, list of executed control commands via the voice menu, transmitted by SMS, software updates, date and time of loss/recovery power supply (network).
    • Remote software update without disconnecting the module itself and dismantling it.

    For which boilers is the GSM thermostat “ZONT H-1” suitable?

    The “ZONT H-1” module is essentially a simple room thermostat, but only implemented on a hardware platform using a GSM/GPRS modem and WEB technology. The principle of its operation and the method of connection to any gas or electric boiler is exactly the same as that of conventional thermostats. It connects to the connector for the room regulator and controls the boiler, maintaining the set temperature according to the readings of its temperature sensor. To do this, the thermostat turns the boiler on or off by closing the contacts of its output relay.

    Thus, if your boiler provides the ability to control commands from a room thermostat, then the ZONT H-1 thermostat can be used with it.

    Technical characteristics of "ZONT H1"

    Supply voltage 10-28 V
    Maximum current consumption 150 mA
    Number of inputs 2
    Output dry contact (make/open) 1
    Type of connected wired temperature sensors DS 18S20
    Type of connected radio thermal sensors ML-703
    Total number of simultaneously connected temperature sensors 10
    Maximum permissible length of cable with temperature sensors 100 m
    Maximum current through relay contacts 1000 mA
    Maximum voltage of switched relay contacts ~120 V, DC 24 V
    Voice interface There is
    WEB interface There is
    1-Wire interface There is
    Operating temperature range from -30 to +55 °С
    GSM modem frequency ranges 800, 900, 1800, 1900 MHz
    Data link GPRS
    GSM antenna external
    Internal non-volatile memory There is
    Time to reach operating mode no more than 50 seconds
    Average service life 7 years
    Dimensions 77 x 86 x 33 mm
    Weight no more than 200 g
    Housing material ABC plastic

    Delivery set "ZONT H-1"

    • Thermostat " GSM-Climate ZONT H-1."
    • Mounting base.
    • Power adapter from 220 V mains.
    • GSM antenna.
    • Wired temperature sensor.
    • Screw terminal blocks.
    • SIM card.
    • User's Guide.
    • Warranty card.
    • Branded packaging.

    Smart thermostat ZONT (ZONT models H-1, H-1V and H-2) is designed to meet the needs of vacation home users. The peculiarity of the situation is when there is no one in the house, but you need to be sure that the heating system is working. Moreover, the inertia of the heating system requires changing the boiler mode long before the owners arrive. All this can be solved with the help of our devices and Internet service. ZONT.

    Features and principle of operation

    Thermostat Feature ZONT-H is that it is focused on the use of the Internet. Now the main trend in this area is cloud service and this is exactly how the thermostat works. Unlike most competitors, it does not have a home control panel. All monitoring and control operations are performed using either a personal computer or mobile devices- smartphone or tablet. This significantly reduces the cost of equipment, while at the same time allowing the user to control the situation wherever he is.

    Thermostat ZONT - H It also works when the connection is lost, executing a predetermined program, for example, a weekly schedule. Additionally, it is possible to use control commands in the form of SMS text and even using the voice menu.

    The user has the opportunity to use a very functional and powerful graphical interface through a web browser or mobile application. Convenient and visual graphics, information messages and settings are available. Data from the product is stored on the server and the user can view the entire history of events and parameters. The user interface is carefully designed and highly appreciated by numerous customers.

    To meet the needs of various user groups, various models, differing in the type of connection - GSM or WiFi. Structurally, some models are made in a small-sized case of their own design, others - in a standard case on a DIN rail for installation in an electrical cabinet.

    The thermostat has 2 inputs for connecting various additional devices.
    On Input 1 can be connected: or ; or C "Boiler failure" signal; or External room thermostat.

    On Entrance 2 can be connected: or Security sensors and detectors; or C "Boiler failure" signal; or External room thermostat; or Interface OpenTherm And Radio module ML-489.

    - Security sensors and detectors , connected to one input must be of the same type in connection method. Number of sensors in the loop - ICD, MKD, etc. no more than 10 pieces; water leak and gas leak detectors no more than 5 pcs. The maximum distance of the latter in the train is 100 m.

    - WITH “Boiler failure” signal. For control technical condition boiler and generating an alert about its emergency condition, the thermostat can be connected to the emergency output of the boiler.

    - Room thermostat . By connecting an external room thermostat, it becomes possible to control the boiler either through ZONT-H 1 and through an external room thermostat, the choice of how control is carried out is made remotely via the Internet service or SMS command "Manual mode".

    When operating from an external thermostat, remote monitoring of the room temperature and all alert modes (accidents, power loss/restoration, alarm events, etc.) will be maintained.

    - Radio module ML-489. Thermostat interface module ZONT with radio devices It provides reception and relaying of information from radio devices to the ZONT server

    For boilers that have a computerized OpenTherm interface There is an adapter that allows you to expand the control and monitoring functions and ensure fuel savings through advanced system operation algorithms.

    How to choose and operate thermostats correctly ZONT?

    Models ZONT H-1 and ZONT H-1V have a GSM communication channel and are designed for very little Internet traffic. Therefore, the price of the subscription fee to the mobile operator is minimal

    The ZONT H-2 model has a WiFi communication channel and is used where a wireless local network already exists.

    1. Internet traffic is about 60 MB per month*

    *indicated taking into account rounding to 100kb per hour

    It is important to take into account that the actual consumption of Internet traffic highly depends on the nature of the device’s use and the quality of the connection. Accordingly, the worse the connection conditions, the more often the device reconnects to the server, and the more traffic is consumed.

    To make the subscription fee easily predictable, we recommend choosing tariffs with unlimited traffic.

    Many operators offer tariffs in which the Internet speed drops when a certain limit is reached. Such tariffs are also good because ZONT devices do not have special requirements for connection speed.

    If you choose a tariff with per-megabyte payment for traffic, then pay attention to the amount of traffic rounding. At great importance rounding (for example, more than 100 KB), the operator may count many times more traffic than the device actually consumes. The smaller the rounding size, the better.

    2. Calls and SMS

    ZONT devices use voice calls and SMS messages only for alarm notification, therefore, choose a tariff based on the expected number of alerts.

    Attention! There are tariffs that are incompatible with work ZONTA

    • From November 2015 on MTS Smart tariffsInternet operation is blocked in 3G modems . Along with modems, the operator also blocks our devices.
    • Option "Tablet XS" from MegaFonDesigned for use on tablets only , and in ZONT devices it either does not work at all or leads to constant loss of communication.

    Important!

    Flashing is an extremely desirable step when you first turn it on. The fact is that in production the product receives the current firmware, and the user prefers to have the latest one. So we recommend that you reflash the thermostat before using it.

    Flashing should be carried out under user control. Since the communication channel is usually unreliable, you need to make sure that the flashing procedure is successful and the product is connected again.

    Video about ZONT H1V:

    YouTube Video

    How to set up a power outage alert

    Settings - thermostat settings - input No. 2 - "panic button"
    - - emergency input polarity - "ground fault"
    - -alerts-alarming events-"your phone"-"envelope"
    -save

    Instead of "input 2" you can also use "input 1". For ZONT-H1V it’s basically the same, just different contacts.

    The difference between ZONT H-1V and ZONT H-1 is as follows:

    • the relay in H-1V holds 220V. The relay in H-1 is rated for 120V;
    • ZONT H-1V has a 220V->5V adapter for converting a high-voltage boiler alarm signal (available in Vaillant) into a low-voltage one for the ZONT input;
    • relays have opposite logic - the information is outdated, it corresponds to products manufactured before xxx 2015 (see the section “connection to the boiler”):
      • ZONT H-1 - the boiler heats up when the relay is energized. If the power is lost, the relay turns off. Internal battery does not power the relay, so it does not help turn on the relay. Therefore, when planning the system layout, you need to take this into account, for example, power the Umbrella and the boiler from the same UPS;
      • ZONT H-1V - the boiler heats up when the relay is de-energized. Therefore, if the power goes out, the relay turns off, but the boiler turns on with the relay contacts. The umbrella can be hung without a UPS, it will know about a power failure and send an SMS about it;
    • The battery in the H-1V is built-in, while in the H-1 it is not even included in the basic kit. It can be purchased in addition;
    • and most importantly, the firmware of both options is the same. Schemes, almost the same. Different cases;

    Connection to the WAMOS QX boiler (EVAN)

    (This scheme is not suitable for other Evan boilers)

    The umbrella, wanting to turn on the boiler, closes 1-3, opens 1-2.

    The boiler has an IN input. Although it is called the air temperature sensor input, we use it as the thermostat input. You can use another, alternative input - a heated floor sensor. They are essentially the same.

    The ZONT H1 relay is connected as follows. The central contact of the relay (1) is connected to the IN input. The normally closed relay contact (2) is connected to the “-” input. The normally open relay contact (3) is connected to the “+” input.

    To make it clear, the “+” and “-” contacts of the boiler are connected to the 5V power circuit. As a result, the ZONT H1 relay switches them to the IN input.

    Test of the first start-up of the boiler, using the example of EVAN WARMOS QX

    1. Set the set temperature lower than in the room. Make sure that the boiler inlet is ZERO. The boiler should not heat;
    2. Set the set temperature higher than in the room. Make sure that the boiler input is +5V. Actually, the boiler must heat the water, and without a multimeter it will be clear that the pipe is getting hotter and hotter.

    Thermal sensor

    All sensors are connected in parallel. The web interface has a procedure for assigning a “own name” to each sensor.

    Please note that there are many modifications of these sensors on the market and they differ in discreteness. The product comes with a DS18S20 sensor with a resolution of 0.1 degrees. Sometimes users buy sensors externally. Therefore, we present additional information By different types sensors:

    • DS1820 is an old, discontinued model. It differs in its elongated body from all new models. It has a capacity of 9 bits, which leads to a discreteness of 0.5 degrees;
    • DS18 S 20 - Has a capacity of 12 bits, recommended for use. Note that manufacturers label the microcircuit as DS1820, so it can only be distinguished by the size of the case, it is shorter;
    • DS18 B 20 - Has a different operating protocol. The ZONT H1 program supports 12 bits for it, that is, a discreteness of 0.1 degrees;

    If you already have a room thermostat and want to include ZONT - H in the gap between the boiler and the room thermostat?

    Yes, now it is possible. To do this, you need to connect the room thermostat to one of the thermostat inputsZONT.

    This connection allows you to control the boiler remotely (via ZONT ) and manually, according to commands from this room thermostat. The choice of control method is carried out via the Internet service or SMS command "Manual mode".

    When operating from a room thermostat, remote temperature monitoring and all alert modes are maintained (about an accident, power loss/restoration, alarm events, etc.).

    Many people are interested in how the discrete inputs of ZONT H are made?

    • Input 2 - may have options:
    • Input 1 - may have options:

    Relay contacts

    Relay diagram:


    It can be seen that when the power is turned off, contacts 1 and 2 are closed. This must be taken into account, keeping in mind the situation with power failure. The boiler usually turns off when the control contacts open and turns on when they close. But there are also opposite options!! Then an external relay is required, which inverts the operating logic. This relay is switched on by the ZONT H contacts.

    Often ZONT H is turned on together with the boiler via an Uninterruptible Power Supply (UPS).

    First steps to turn on the GSM thermostat ZONT H

    1. Preparation and setup
      1. Buy a SIM card ( standard size, no micro- and nano-SIM) and top up its balance. Minimum requirement - 5-10 MB and 10 SMS (while you play with the settings, you’ll just spend it);
      2. Before using it in the product, it is better if you already have a personal account set up on the telecom operator’s website. It will help you see the dynamics of money and traffic consumption and solve emerging problems.
      3. Have a suitable place where you record and save accounts and passwords. You will need to do this for your SIM card personal account, for the ZONT web interface, and for the access password from your phone. It's amazing how often we forget passwords :-)
      4. Before connecting the device to the boiler, set it up “on the table”:
        1. Register yourself on the sitehttps://zont-online.ru/
        2. Register the device on the same site - there is a “add device” sign there.
        3. Install the SIM card (open the receiving clip, fold it up, insert the SIM card into the slots with the cut corner facing up, soldering the SIM card to the contacts)
        4. Connect the included antenna (there is no internal antenna, so this is required). Please note that if the room is in the basement or in an area of ​​poor reception, then the antenna should be placed as high as possible
        5. Connect the temperature sensor and power supply (AC adapter).
        6. < > Dial an SMS in your phone about resetting to factory settings. There are a lot of letters, and the time for sending will be limited, so we advise you to type the text in advance. Don't send SMS yet.
        7. < This item is optional. Needed if there is no web interface> Enter the SMS text into your phone about the registration of your phone. There are a lot of letters, and the time for sending will be limited, so we advise you to type the text in advance. WITHwrite serial number small letters and what needs to be done after the serial number space and be sure to write the word " Telephone ", and write the number without any hyphens between the numbers. Do not send an SMS yet.
        8. Connect the connectors and apply power
        9. Wait for one of two options for a green signal on the device:
          1. so that it lights up constantly and sometimes goes out for a split second several times in a row (indicates that there is a network and the signal level is normal). This is an option when there is both a GSM connection and a connection to the server;
          2. so that it flashes in a series of flashes, at least two flashes, with a pause between flashes.This is an option when the GSM connection is established, but there is no connection to the server. In this case, SMS can be used.
        10. EIf the green indicator flashes only once for a short time, it means there is no GSM connection and there is no point in sending SMS.
        11. < This item is optional. Required if the SIM card is NOT a MEGAFON or the device was released before September 2015> Send an SMS with the APN access point setting. How to do this is written in the instructions.
        12. Log in to the web interface and wait for the device to appear connected. After this, you can add a phone number for voice and SMS notifications in the web interface settings. If this is done, then there is no need to send an SMS with the same number. That is, paragraph 14 is not required.
        13. <This item is optional. Most likely, it will be required if the procedure is repeated. If for some reason the first pass didn’t work out>Send SMS about factory reset.After resetting to factory settings, you will need to remove the device from the list and add it again.
        14. <This item is optional. Needed if there is no web interface>Send SMS about the registration of your phone. Wait for the response message “phone number has been established.”
    2. Before connecting to the boiler
      1. Try to find out the type of connection (normally closed or normally open), it depends on which contacts on the block the wire from the boiler is connected to. To do this, you need to study the documentation for the boiler. You can simulate it by connecting a jumper and make sure that the boiler reacts correctly
      2. Install the device and sensors permanently
    3. Connection
      1. Connect the wires from the boiler
      2. Change modes and monitor the boiler’s reaction
      3. As soon as the boiler begins to respond adequately to the control input, you can begin setting up modes

    Battery backup and UPS

    The backup battery in the ZONT thermostat is intended only to notify the server and owner via SMS about the loss of the main 220V power supply. Usually the boiler cannot operate without main power, so there is no point in controlling the boiler in this situation.

    Sometimes the user installs a UPS - an uninterruptible power supply. It connects to the boiler and it is logical to power ZONT from it. But a problem arises: ZONT does not recognize the loss of the main 220V power supply. In this case, you can select “Boiler emergency” for notification. You can buy any cheap power supply or charger with an output voltage of 5V and connect it to this input. The circuit, unfortunately, requires a couple more parts - a resistor (any) and a diode (any):


    Configure Input 2 in the web interface to the "ground fault" mode.

    Some UPSs have a main power failure output. Then you just need to connect it to Input 2 and select one of the “Input Polarity” options - “open” or “short”.

    It is important to add that SMS and web notifications will be not only when an accident occurs, but also when it disappears.

    Color of the temperature sensor wires included in the delivery kit

    The two-strand wire used is misleading to some. It’s worth taking a closer look; let’s call the one that’s “more red” “red.” The one that is “blacker” will be called “black”. If it's completely unclear, don't be afraid. Turn it on at random and if the sensor works, you will see the readings in the web interface. You can heat one in order to distinguish between several connected in parallel.

    How often is data sent to the server?

    Sensor readings are sent to the server once a minute. Emerging events (exceeding permissible limits, etc.) - immediately upon occurrence.

    Some don't important parameters(information about balance, GSM signal level, etc.) are sent upon request from the server. The server sends requests for this data once every minute or two, but only if the user is online in the ver-interface or mobile application.

    If the web interface does not sense user activity for 10 minutes, it goes into “sleep mode”. In this mode, the web interface stops updating data from the server as you move the mouse. Temperature and event data continues to be sent to the server in real time.

    Explanations for setting Input 1

    General note. On the "Status" tab, the "Security" button appears for the options "motion sensor", "motion sensor with delay", "short-to-minus sensor", "minus-opening sensor". This button can be turned on or off, that is, you can make the input active or disabled.

    For other options, the "Security" button is absent, that is, the input is considered to be constantly active.

    • "not used" - should be selected if it is not connected. Otherwise, you may get an alarm
    • "delayed motion sensor" - triggered when the circuit opens. There is a delay of 30 seconds. The web interface displays the message "motion detected"
    • "motion sensor without delay" - triggered when the circuit opens. The web interface displays the message "motion detected"
    • "water leakage sensor" - an analog input is used, triggered at a voltage less than 2.4V. The web interface displays the message "water leakage detected"
    • "gas leak sensor" - triggered when the circuit opens to ground. The web interface displays the message "gas leak".
    • "panic button
    • "short circuit to negative sensor" - triggered when there is a ground fault
    • The ZONT H-1V thermostat model has a 220VAC relay, but also limited current.

    A large number of materials on the Internet are devoted to setting up the ZONT EVAN H-1 GSM modem. This article is devoted to setting up an analogue called ZONT H-1 V, in a modular design for a DIN rail. made of gray plastic, the top cover with a logo, removable. The connectors are located at the bottom.

    The kit includes a modular power supply also for DIN rail installation. There is no power cord with plug. Output - 12 Volts DC. Power is connected to pins 9 and 7, do not confuse polarity!

    The protective cover of the modem is removed using a miniature flat screwdriver, under it there is a SIM card slot, LEDs and a jumper for turning on the battery. The function of LEDs is the same as in

    The passport indicates the assignment of the contacts in the connector. Let me immediately draw your attention to the fact that there is an error in the passport: normally closed contact - number 3, not 2, as indicated in the passport. We verify this by measuring the resistance between the contacts.

    When the yellow LED is on (the boiler is working), contacts 1 and 2 are closed. That is, the 2nd contact is normally open. All gas boilers with a jumper in the thermostat circuit are connected to contacts 1-2 of the GSM modem (the jumper is first removed).

    We connect the temperature sensor in accordance with the diagram in the passport on pins 4 and 6. We don't confuse polarity!

    The modem kit also includes a 220/12V converter to convert a 220 Volt emergency signal to an acceptable value of 12 Volts. This voltage can be safely applied to input “8” of the GSM modem.

    The modem settings in your ZONT-ONLINE personal account do not differ from the modem settings.

    Additional technical advice can be obtained online, to do this, fill out Technical support request form.

    koreada.ru - About cars - Information portal